Micropipettes

Pipettes for ergonomic work in the laboratory: Discover micropipettes of the Transferpette® family from BRAND. Micropipettes available from 0.1 µl to 10 ml as single-channel or multi-channel micropipettes, mechanical or electronic – ideal for PCR, ELISA, cell culture, routine analysis and other everyday laboratory tasks. With the air displacement pipettes Transferpette® S, Transferpette® pro and the Transferpette® electronic you benefit from ergonomic design, high accuracy and reproducible results. Autoclavable components, ISO 8655 compliance and, on request, DAkkS calibration support your QM requirements. Thanks to optimally matched pipette tips and broad compatibility, you work safely and efficiently. Find the right BRAND micro pipette for your application and order in our online shop.

Shop By
Sort by
Number of channels
Set Descending Direction
Page
View as Grid List

Items 9-15 of 15

Set Descending Direction

Laboratory pipettes

Pipetting is one of the most frequent tasks in the laboratory. Discover the Transferpette® laboratory pipette family: ergonomic air displacement pipettes for accurate, reproducible pipetting in laboratory applications. They cover volume ranges from 0.1 µl to 10 ml. The micropipettes are available in various versions: Single-channel and multi-channel micropipettes (8/12-channel) for individual samples and microplates; Transferpette® S and Transferpette® pro – mechanical pipettes as variable or fixed models; Transferpette® electronic – electronic pipette with programs for pipetting (standard or reverse), mixing, and gel loading. All Transferpette® models have a separate tip ejection button. This prevents accidental ejection of the tips. The micro pipettes are calibrated within the scope of test equipment monitoring in accordance with EN ISO 8655. All models of the Transferpette® pipettes feature the unique Easy Calibration technique, which allows adjustment without tools. Autoclavability: Depending on the model, either the complete pipette shaft (Transferpette® electronic) or even the entire pipette (Transferpette® S & pro) can be autoclaved at 121 °C (2 bar) in accordance with DIN EN 285. Tip cone: The pipette and the pipette tip form a system. Both system components are developed by BRAND and are optimally matched to each other. This ensures optimal compatibility of the Transferpette® pipettes with the pipette tips and filter tips from BRAND. Due to the universal design of the tip cones, tips from other leading manufacturers can also be used.

Mechanical pipettes

The Transferpette® S and Transferpette® pro are mechanical micropipettes for precise pipetting in the laboratory – available as single-channel or multi-channel pipettes. Both the Transferpette® S and the new Transferpette® pro enable true one‑hand operation. With volume‑change protection as well as a universal tip cone for tips from various manufacturers. The Easy Calibration technique enables permanent adjustment without tools. Lightweight, robust, and completely autoclavable – ideal for changing laboratory conditions and high QM requirements. See for yourself the advantages of the Transferpette® S & pro air‑cushion pipettes. In addition, the Transferpette® pro offers even more flexibility with an adjustable finger rest, a temporary adjustment function, and the extended volume range. The integrated counter protection of the Transferpette® pro provides additional protection for the mechanism and makes the pipettes particularly robust. Try it yourself and choose the pipette that fits your tasks and requirements.

Electronic pipettes

The Transferpette® electronic is an automatic micropipette that combines the proven characteristics of mechanical micropipettes with the advantages of electronic instruments. The electronic pipette is available as single-channel and multi-channel micropipette and supports fast, intuitive workflows through a hand‑friendly design, balanced weight distribution, and clear, comprehensible software. Independent, neutral user tests confirm the ergonomics and ease of use of the product and system. With the Transferpette® electronic pipette, laboratory users benefit from intuitive programs and ergonomic relief. Whether pipetting, mixing, reverse, gel loading or dispensing – the electronic pipette from BRAND accelerates standard processes and supports reliable results. Try it now and be convinced. The single-channel micropipette Transferpette® electronic was the world’s first micropipette to be awarded the “Ergonomics tested” certificate from TÜV Rheinland/Berlin-Brandenburg.

Frequently Asked Questions (Micropipettes)

What do I have to do before autoclaving and cleaning my Transferpette® S -8/-12?

Transferpette® S -8/-12 pipettes need not to be disassembled before autoclaving. The pipettes are completely autoclavable at 121°C (2 bar), acc. DIN EN 285. But the volume adjustment must be set to an available numbered volume (e.g., 11.25 or 11.26 but not between), with the volume-change protection set fully unlocked. We recommend the use of sterilization bags. Further information on the procedure can be found in the manual in chapter "Disassembling the manifold".

Do I have to lubricate my Transferpette® pipette after every autoclaving?

If the pipette is frequently autoclaved, the piston should be oiled with the supplied silicone oil in order to preserve smooth movement. See the appropriate operating manual for more information!

Can I order Transferpette® pipettes DAkkS calibrated?

All our liquid handling instruments can be ordered DAkkS calibrated with certificate for a certain additional charge per piece. For ordering please add "DAkkS/...." as a prefix to the corresponding catalog number, e.g., DAkkS/7036 00 for a Transferpette® -8, 0.5-10µl, DAkkS calibrated. The current price list will provide more details on the additional charge for your requested instrument.

How do I do maintenance for my Transferpette® S -8/-12?

To inspect the pistons and seals for contamination unscrew the manifold from the hand grip and disassemble it. Information about maintenance is given in the operating manual in the chapter "Maintenance".

What is the regular interval the seals of Transferpette® multichannel pipettes have to be replaced?

There is no concrete interval determined. It depends on the handling of the instrument and the tips used. Find more information in the appropriate operating manual.

How can I do maintenance for my Transferpette® S?

To inspect the piston and seal for contamination unscrew the pipette shaft from the hand grip and disassemble it. Information about the steps is given in the manual in chapter "Servicing and Cleaning". A tool is not necessary.

The piston of my Transferpette® S is difficult to move. What can I do?

A contaminated piston could be the cause. After cleaning you should oil the piston with a very thin layer. When using a pipette with a volume range of 5ml or 10ml also the seal should be lubricated according to the manual chapter "Servicing and Cleaning".

At what wave length is the UV resistance of Transferpette® pipettes tested?

The UV resistance of Transferpette® pipettes from BRAND is tested at a wave length of 254nm.